Preventative Maintenance and Cleaning

Preventative Maintenance and Cleaning


Periodic maintenance is essential for safe and proper operation of the Smart Agitation System. Replace worn components immediately.

Check the bolt torques to assure no movement over time.


Component

Inspection Interval

Maintenance / Replacement Schedule

Paddle

60-90 Days

Yearly

Sphere Door Lock

90-120 Days

Yearly

Sphere Filter Plate

60-120 Days

Yearly

Spin Flow Vibration Tank

30-60 Days

Yearly


Dumping and Cleaning:

  • Turn off and unplug the unit before cleaning.
  • Wipe down the exterior with a damp cloth.
  • Do not use harsh chemicals or abrasive materials.
  • Close the drain valve and verify the containment cart is in place with the valve closed.
  • Press the Auto icon on the touchscreen and select 'Yes' to switch to manual mode.
  • In manual mode, press the lower portion of the Agitation tank icon to prompt the door to open.
  • Select 'Yes' when prompted to confirm door open action. Allow the biomass to slide into the containment cart.
  • Use the integrated sprayer balls to rinse the agitation tank, door, and door seal.
  • Close the door and begin the next batch.
  • Between Washes: Spray down the walls and floor of the SAS.
  • End of Day: Run a cleaning cycle with water and isopropyl alcohol (or ethanol).
  • Regular Maintenance: Inspect for wear and replace components as needed.

Inspecting the Unit:

  • Regularly check for any signs of wear or damage.
  • Ensure all connections are secure.

Storage:

  • Store the unit in a cool, dry place when not in use.

Pro Tip:

  • If no other processing is scheduled, leave the agitation door open until the next operation.
  • Pre-soak material before washing to save time.
  • Pre-freeze trays to manage excess freshly washed hash.